CAL-TEC SOLUTIONS, LLC
  • HOME
  • ROSEMOUNT TRANSMITTERS
  • FOXBORO TRANSMITTERS
  • FISHER VALVES
  • CAREERS
  • CONTACT
Picture
Remanufactured Rosemount Transmitter
Remanufacured Rosemount
3051S Series SMART® Pressure Transmitter
Electronic Absolute Pressure, Electronic Level Measurement, Differential Pressure, Electronic Differential Pressure, Electronic Gauge Pressure, Gauge Pressure, Pressure Measurement, Absolute Pressure, Level Measurement ​

Description - The 3051S Series SMART® Pressure Transmitters are offered in a variety of configurations for differential, gauge, liquid-level, flow and specific gravity measurement applications.

Typical Application:
3051S_CA: Absolute Pressure
3051S_CD: Differential Pressure for flow or level measurement
3051S_CG: Gauge Pressure
3051SAL: Flanged-mounted Liquid Level for open- or closed-tank application
3051S_TA: Direct Mount Absolute Pressure
3051S_TG: Direct Mount Gauge Pressure

​Output
  • Two-wire 4-20 mA is user-selectable for linear or square root output. Digital signal based on HART Protocol.
Range Limits
  • 3051S_CA: 0-0.167 to 0-4000 psia
  • 3051S_CD: 0-0.01 in H2O to 0-2000 psid
  • 3051S_CG: 0-8.3 in H2O to 2000 psig
  • 3051SAL: 0-8.3 in H2O to 0-300 psi
  • 3051S_TA: 0-0.3 to 0-10,000 psia
  • 3051S_TG: 0-0.3 to 0-10,000 psig

Reference Accuracy
3051S_CD/CG, Ranges 2-4:
  • Classic: +0.035% of span, For spans less than 10:1: ±[0.015 + 0.005(URL / Span)]% of span
  • Ultra: +0.025% of span, For spans less than 10:1: ±[0.005 + 0.0035(URL / Span)]% of span
  • Ultra for Flow(3051S_CD Only, Ranges 2-3): +0.04% of reading up to 8:1 DP turndown from URL, or ±[0.04 + 0.0023(URL / Reading)]% of reading to 200:1 DP turndown from URL
3051S_CD/CG, Range 5:
  • Classic: +0.065% of span, For spans less than 10:1, ±[0.015 + 0.005(URL / Span)]% of span
  • Ultra: +0.05% of span, For spans less than 10:1, ±[0.005 + 0.0045(URL / Span)]% of span
3051S_CD/CG, Range 1:
  • Classic: +0.10% of span, For spans less than 15:1, ±[0.025 + 0.005(URL / Span)]% of span
  • Ultra: +0.09% of span, For spans less than 15:1, ±[0.015 + 0.005(URL / Span)]% of span
3051S_CD, Range 0:
  • Classic: +0.10% of span, For spans less than 2:1: ±0.05% of URL
  • Ultra: +0.09% of span, For spans less than 2:1: ±0.045% of URL
3051S_CA, Ranges 1-4:
  • Classic: +0.035% of span, For spans less than 10:1: ±[0.0065(URL / Span)]% of span
  • Ultra: +0.025% of span, For spans less than 10:1: ±[0.004(URL / Span)]% of span
3051S_CA, Range 0:
  • Classic: +0.075% of span, For spans less than 5:1: ±[0.025 + 0.01(URL / Span)]% of span
  • Ultra: +0.075% of span, For spans less than 5:1: ±[0.025 + 0.01(URL / Span)]% of span
3051S_TA/TG, Ranges 1-4:
  • Classic: +0.035% of span, For spans less than 10:1: ±[0.0065(URL / Span)]% of span
  • Ultra: +0.025% of span, For spans less than 10:1: ±[0.004(URL / Span)]% of span
3051S_TA/TG, Range 5:
  • Classic: +0.065% of span, For spans less than 10:1: ±0.0065% of URL
  • Ultra: +0.04% of span, For spans less than 10:1: ±0.004% of URL
3051SAL, Ranges 2-5:
  • Classic: +0.065% of span, For spans less than 10:1: ±[0.015 + 0.005(URL / Span)]% of span
  • Ultra: +0.055% of span, For spans less than 10:1: ±[0.015 + 0.005(URL / Span)]% of span

Power Required
  • 3051S: 10.5-42.4 V dc with no load
  • 3051S with Advanced HART Diagnostic Suite: 12-42.4 V dc with no load

Materials of Construction
3051S_C:
  • Sensor Wetted Parts: 316L SST, Hastelloy, Monel, Tantalum, Gold-plated SS, Gold-plated Monel
  • Sensor Fill Fluid: Silicone, Inert (Halocarbon)
  • Coplanar and Traditional Flanges and Adapters: Cadmium and Nickel-plated CS, 316 SST, Hastelloy, Monel
3051S_T:
  • Sensor Wetted Parts: 316L SST, Hastelloy
  • Sensor Fill Fluid: Silicone, Inert (Halocarbon) (3051S_TG Only)
3051SAL:
  • High-side Diaphragm: 316L SST, Hastelloy C-276, Tantalum
  • High-side Fill Fluid: DC 200 Silicone, DC 704 Silicone, Syltherm 800, Syltherm XLT, Inert (Halocarbon), Neobee M-20, Glycerin and Water, Propylene Glycol and Water

Process Flange
  • Carbon Steel, SST

​Options
  • Mounting Bracket, LCD Meter, Transient Protection, Manifold
  • (other options available)
Our Promise...
We will provide our clients with unsurpassed value, marquis levels of service and quality, with safety and efficiency as the cornerstone. This is accomplished only by employing and developing the most qualified, the most skilled resources available and by developing individuals who share our commitment and tradition of “Best of Class” services that consistently exceeds customer expectations.

Location

Contact Us

Website design by SLS Digital Consulting

Phone

Email

Address

337-488-9322
[email protected] 
2140 Kirkman Street, Ste B
Lake Charles, LA 70601
  • HOME
  • ROSEMOUNT TRANSMITTERS
  • FOXBORO TRANSMITTERS
  • FISHER VALVES
  • CAREERS
  • CONTACT